- 53 -
LP PRESSURE
REGULATOR
NG PRESSURE
REGULATOR
GAS VALVE BODY
SCREWS
PILOT HOOD
PILOT ORIFICE
USE
7
16
"
WRENCH TO
LOOSEN HOOD
NATURAL TO LP GAS CONVERSION
Kit # HA-52-00145 for Mendota Model M-50
This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer’s instructions and all applicable
codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly, a fire, ex-
plosion or production of carbon monoxide may result causing
property damage, personal injury or loss of life. The qualified ser-
vice agency is responsible for the proper installation of this kit.
The installation is not proper and complete until the operation of the
converted appliance is checked as specified in the owner instructions supplied
with the kit.
Caution
: The electrical supply to the fireplace must be turned off prior to per-
forming the conversion. The gas supply must be shut off prior to disconnecting
the electrical power.
ORIFICE SIZES REQUIREMENT:
A Natural Gas to LPG conversion kit #HA-52-00145 must be ordered and installed to convert the M-50 Fireplace to burn
LPG.
LP Conversion Kit #HA-52-00145 contains the following parts: One LP Pressure Regulator, One LP Pilot Orifice Thimble,
One Cap Orifice
drill #54 (for rear burner) and One Cap Orifice drill #51 (for front burner). Specifically, identify the Rear
and Front Burner Cap Orifices. Use proper sized drill bits’ shaft ends to verify orifice sizes.
WARNING: IT IS OF THE UTMOST IMPORTANCE THAT THE CORRECT BURNER ORIFICE BE INSTALLED FOR
BOTH THE REAR AND FRONT BURNERS.
1. Turn off gas supply at the appliance service valve. Identify the Pressure Regulator on the Valve Body; see Figure 13
on PAGE 45.
2. Using a ¼” flat blade screwdriver, remove 3 screws that
secure the NG Pressure Regulator to the gas valve body
and remove NG Pressure Regulator as shown above.
Identify the pressure regulator spring that is located in the
center of the black rubber gasket. Discard both the black
rubber gasket and spring.
3. Install the new LP Pressure Regular onto the gas valve
body in the same position and orientation as the NG Pres-
sure Regulator you removed in Step 2, above. The LP
Pressure Regulator can only be mounted in one position.
Secure the LP Pressure Regulator in place using the 3
screws you removed in Step 2. Tighten down using a ¼”
flat blade screwdriver.
4. Remove both Rear and Front Burners. Locate and Identify
the Rear Burner Orifice Spud and the Front Burner Orifice
Spud. Both Front
and Rear Orifice
Spuds are re-
moved and in-
stalled using a ½”
deep well socket
and ratchet.
5. Install Rear Burner Orifice #65-14-00054(#54 drill) for the Rear Burner.
Tighten down securely.
6. Install Front Burner Orifice #65-14-00051 (#51 drill) for the Front Burner.
Tighten down securely.
7. Install pilot orifice thimble #05-04-00036 (.014”) see Figure 15 for location.
Remove and install pilot hood with 7/16” open-end wrench. (Pilot orifice
thimble is located inside pilot hood base).
8. Re-assemble pilot hood. Tighten down until pilot flame hood that is directed
towards thermocouple is aligned properly with thermocouple.
Figure 38
Figure 39
DETAIL A
REAR
ORIFICE
FRONT
ORIFICE