Mendota GREENBRIAR M-50 Operations Instructions Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
- 47 -
BLOWER SYSTEM INFORMATION
WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing.
Dual blowers are provided as standard equipment with this M-50 fireplace. The dual blowers have an air output rating
of 210 CFM (in free air). This fireplace is designed to operate with the blowers turned OFF or ON. Turning the blower
on increases the overall efficiency of this fireplace and aids in distributing and circulating heat to the room this fireplace
is installed in.
BLOWER OPERATION
The blower speed control (rheostat) supplied with this blower system can turn the blowers ON or OFF and infinitely
regulate the speed of the blowers. The blower output can be regulated by turning the rheostat knob..
NOTE: There will be a time delay in blower operation during "heat-up" (approx. 15 minutes) and extended blower op-
eration during "cool-down" of unit (approximately ½ hour).
Figure 35: BLOWER WIRING DIAGRAM
1 1 15-02-00064 BLOWER, RIGHT HAND, J238-100-10101
2 1 15-02-00065 BLOWER, LEFT HAND, J238-100-10100
3 1 05-01-00157 SNAP DISC
4 1 10-01-00046 RHEOSTAT w/ OFF
ITEM
NO.
QT'Y
PART
NUMBER
DESCRIPTION
M-50 BLOWER KIT REPLACEMENT PARTS LIST
Page view 46