“FIRST TIME” PILOT LIGHTING INSTRUCTIONS
IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have been completed!
CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before attempting to relight the pilot.
1. Make certain that any manual gas supply shut-off valves located upstream of fireplace are open and the receiver and the remote
control transmitter are in the "OFF" position. Make certain that the receiver harness is connected to the receiver properly.
2. Make certain that 120VAC power cord is connected to an electrical outlet.
3. Insert Batteries in the Receiver (Receiver batteries are optional if AC power is connected) and the Remote Transmitter. Note the
polarity of batteries and insert as indicated on the battery compartment covers.
4. For “First Time Lighting”, Remove the Glass Door. This is required to purge the gas line of air and to inspect the pilot lighting
spark.
5. Slide the receiver switch to “REMOTE”. Locate the “Standing Pilot ON/OFF Switch”. See Figure 1. Toggle “Standing Pilot
ON/OFF Switch” to “ON”. You will hear a series of clicks and after a few seconds, you will hear sparking at the pilot spark elec-
trode.
6. Allow adequate time for the air in the gas-line to purge. The control system will stop sparking after 30 seconds if the pilot light
does not light. After a 30 second delay the control system will start sparking again for 30 seconds more. If the pilot light does not
light after the third 30 second spark event, the system will enter “Lock-out” mode. To unlock from “Lock-out” mode, slide Re-
ceiver Switch to “OFF”, wait 30 seconds and slide back to “Remote”. Repeat this sequence until the pilot flame lights and the pi-
lot is burning steadily.
LOCK OUT MODE: If the pilot light does not light after the third 30 second spark event, the system will enter “Lock-out” mode. To
unlock from “Lock-out” mode, slide Receiver Switch to “OFF”, toggle Standing Pilot Light On/Off Switch to OFF, wait 30
seconds and slide Receiver Switch back to “Remote”.
7. Once the pilot flame is lit and well-established, close glass door. WARNING: NEVER IGNITE MAIN BURNERS WITH
GLASS DOOR REMOVED OR OPEN. Doing so will lead to damage to pilot flame sensor and spark electrode wire leads.
8. Slide switch on Receiver to “ON”. All burners should ignite and run at “high-fire”. Slide Receiver switch to REMOTE after 15
seconds. Burner Flames will extinguish.
9. Perform gas inlet and outlet pressure tests and leak tests on field installed gas fittings and factory installed fittings in the gas valve
compartment, at this time. Note: Burners must be ON to check outlet pressures and to leak test gas train fittings upstream of main
gas valve.