85-03-00889 1 | Page FULLVIEW RECTANGLE DIRECT VENT GAS FIREPLACE HEATER Model FV41-PF2 INSTALLATION INSTRUCTIONS MANUAL DOCUMENT NO. FV41-PF2-I
85-03-00889 10 | Page CONGRATULATIONS You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace. This elegant, h
85-03-00889 11 | Page FV41 DIRECT VENT GAS FIREPLACE GENERAL APPLIANCE SPECIFICATIONS HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at
85-03-00889 12 | Page MANTEL CLEARANCES Mantel Clearances for this fireplace may be measured from the top of the convection air opening or the floor
85-03-00889 13 | Page CLEARANCES TO COMBUSTIBLES FROM APPLIANCE SURFACES Figure 2: Clearances to Combustibles 0" CLEARANCEFROM TOP STANDOFF
85-03-00889 14 | Page PLANNING THE INSTALLATION When planning on appliance installation, it is necessary to determine the following information befo
85-03-00889 15 | Page ROUGH FRAMING DIMENSIONS Rough Framing Dimensions The Rough Framing Dimensions must be main-tained to allow this fireplace to
85-03-00889 16 | Page BACKUP DC POWER INLET PORT INSTALLATION Under normal conditions when AC power is available, this appliance is designed to oper
85-03-00889 17 | Page INNER FINISHINGGUIDES(TOP, L &R)OUTER FINISHINGGUIDES (TOP, L & R)FRAMING DEPTH and FINISHING GUIDES The framing dept
85-03-00889 18 | Page FINISHING MATERIALS INSTALLATION All finishing materials that surround this fireplace’s rectangle profile must extend out from
85-03-00889 19 | Page 18" min. Non-combustible Hearthprotection required [SEE HEARTHPROTECTION PAD R-RATING, PAGE 12]112" MAX. THICK HEART
85-03-00889 2 | Page In the Commonwealth of Massachusetts: • Installation must be performed by a licensed plumber or gas fitter; • A CO detector s
85-03-00889 20 | Page GENERAL INFORMATION Your Mendota Gas Fireplace has a state-of-the-art co-axial direct vent, sealed combustion system. This ad
85-03-00889 21 | Page FRONT110VAC INLET14-2 CABLE REQ'DGAS LINE INLET1/2" FNPT REQ'D12116915161414GAS SUPPLY REQUIREMENTS Correct gas
85-03-00889 22 | Page GAS PRESSURE REQUIREMENTS One of the main causes of operating problems with gas appliances can be improper gas pressure! Probl
85-03-00889 23 | Page GENERAL INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local, state and national codes. Refer to t
85-03-00889 24 | Page GENERAL FLUE VENTING INSTRUCTIONS The Mendota Fireplace must be vented using the Mendota approved vent system components. App
85-03-00889 25 | Page EXTERIOR VENT LOCATIONS AND RESTRICTIONS ALL MEASUREMENTS FROM CENTER-LINE OF VENT CAP ∨ - Vent Terminal ∧ - Air Supply Inle
85-03-00889 26 | Page FLUE VENTING COMPONENTS IDENTIFICATION HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher tha
85-03-00889 27 | Page FOUR 90° ELBOWS MAX IF VERTICALLY TERMINATED IN ZONE "B".THREE 90° ELBOWS MAX IF HORIZONTALLY TERMINATED IN ZONE &qu
85-03-00889 28 | Page IMPORTANT VENTING CONFIGURATION NOTES See Figure 14 [MASTER FLUE VENTING REQUIREMENTS CHART]. HIGH ALTITUDE INSTALLATION INFOR
85-03-00889 29 | Page ZERO VERTICALHORIZONTAL TERMINATIONVERTICAL RISEHORIZONTAL TERMINATIONZERO VERTICALDUAL 90° ELBOWSVERTICAL TERMINATIONVERTICAL
85-03-00889 3 | Page Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance. On ne devrait pas placer de vêtements ni d’autre
85-03-00889 30 | Page HZERO VERTICALHORIZONTAL TERMINATIONH = 18 INCHES MAXIMUM45-1/2"42-1/2” ZERO RISE HORIZONTAL TERMINATION The FV-41 Firepl
85-03-00889 31 | Page VONE(1) 90° ELBOWTOP VENTHORIZONTAL TERMINATIONHVERTICAL RISE HORIZONTAL TERMINATION The minimum vertical section required to
85-03-00889 32 | Page Figure 19 Figure 20 APPROVED
85-03-00889 33 | Page VERTICAL THROUGH-THE ROOF VENTING The maximum vertical run of vent pipe is 51 ft. from the top of the fireplace. The fireplac
85-03-00889 34 | Page . Figure 21 1,2,3,4,513159,10111261 FEETMAX.
85-03-00889 35 | Page H2H1V1FOUR 90° ELBOWS, VERTICAL TERMINATION2'4'- 40'3'V1(12" MIN.)12"H1+H2+H35'249'3&a
85-03-00889 36 | Page FV-41 DOOR OPERATION 1. Use the glass latch tool to disconnect the spring latches from the glass frame. Insert tool into hole
85-03-00889 37 | Page INSTALLATION CHECK OFF LIST q Co-axial vent rigid pipe, wall vent cap or roof vent cap must be installed by a Mendota approved
85-03-00889 38 | Page BLOWER SYSTEM INFORMATION WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause
85-03-00889 39 | Page PULL OUT 1/8"ROTATE CLOCKWISE,RELEASE.ACCENTLIGHTHOUSINGDAMPERPOSITIONINDICATORHook LatchTool In Hole.CCW OPENS DAMPERCW
85-03-00889 4 | Page SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW
85-03-00889 40 | Page TROUBLE SHOOTING THE FV-41 FIREPLACE & MAINTENANCE INFORMATION SYMPTOM PROBABLE CAUSES CORRECTIVE ACTION 1. Thin black
85-03-00889 41 | Page MAINTENANCE 1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED. The following procedures must be performed each year by a Me
85-03-00889 42 | Page 1. PUSH REAR END OF BAFFLE BRICK UPWARD ABOUT 1/4 INCHES.2. TIP LEFT BRICK PANEL INWARD AND RELEASE CAREFULLY.1.REMOVE 8 SCREW
85-03-00889 43 | Page WASHERS (2)3/8" COMP X 1/8NPTBRASS FITTINGORIFICEPILOT LIGHT HOODMOTORIZED PRESSUREREGULATORREAR ORIFICEINSIDE HERE.FRONT
85-03-00889 44 | Page LP PRESSURE REGULATOR CONVERSION INSTRUCTIONS WARNING: Failure to position the parts in accordance with these diagrams or fail
85-03-00889 45 | Page LP GAS PRESSURE REQUIREMENTS Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only acce
85-03-00889 46 | Page WARNING DO NOT PROCEED WITH OPERATION OF THIS FIREPLACE UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS! Once the conv
85-03-00889 47 | Page FV-41 VALVE ASSEMBLY REPLACEMENT PARTS FV-41 VALVE ASSEMBLY REPLACEMENT PARTS LIST ITEM QTY PART NUMBER DESCRIPTION 1 1 H
85-03-00889 48 | Page FV-41 GAS IGNITION SYSTEM WIRING DIAGRAM The appliance must be electrically connected and grounded in accordance with local c
85-03-00889 49 | Page TAB #2 USE LARGE PLIERS TOBEND DOWN (4) TABSAS SHOWNGLASSGASKETGLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT 1. Bend Glass
85-03-00889 5 | Page TABLE OF CONTENTS SAFETY AND WARNING INFORMATION 4 TABLE OF CONTENTS 5 SPECIFIC REQUIREMENTS FOR THE COMMON WEALTH OF MASSACH
85-03-00889 50 | Page LISTING LABEL INFORMATION The model information regarding your specific appliance can be found on the rating plate, which is l
85-03-00889 51 | Page MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfac
85-03-00889 52 | Page TAPE SHUT ---------------------------------------------------------------------------------------------
85-03-00889 53 | Page MENDOTA EXTENDED PROTECTION AND LIMITED WARRANTY MENDOTA FV41 DIRECT VENT FIREPLACE Mendota Division of Johnson Gas Applia
85-03-00889 54 | Page Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division WEBPAGE: w
85-03-00889 6 | Page GAS SHUTOFF PROCEDURES 40 MAINTENANCE 41 NATURAL TO LP GAS CONVERSION 42 ORIFICE SIZES REQUIREMENT: 42 LP PRESSURE REGULAT
85-03-00889 7 | Page Specific Requirements for the Common Wealth of Massachusetts The information in this section applies to all installations perfo
85-03-00889 8 | Page FV-41 FULL VIEW GAS FIREPLACE DIMENSIONS OVERALL APPLIANCE DIMENSIONS AND FEATURES VISIBLE GLASS AREA26-1/4" X 29-1/2&qu
85-03-00889 9 | Page TECHNICAL SPECIFICATIONS FOR FV-41 MODEL FV41 High Fire - Adjustable to - Low Fire BTUH. (MODEL FV-41)
Comments to this Manuals