INSTALLATION & OPERATING INSTRUCTIONS
Full View Direct Vent Gas Fireplace Insert
With
Premium Texture Fiber Logs Combustion System
MODEL #E-FV44I ECHO SERIES
MODEL NO. E-FV44i
DOCUMENT: E-FV44i-1011
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l’appareil.
CONSOMMATEUR : Conservez cette notice pour consulta-
tion ultérieure.
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property dam-
age, personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Open windows.
Do not touch electrical switches.
Do not try to light any appliance.
Extinguish any open flame.
Do not use the phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas suppli-
er.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control, which has been under water.
AVERTISSEMENT : Assurez-vous de bien suivre
les instructions donné dans cette notice pour réduire au min-
imum le risque d’incendie ou pour éviter tout dommage
matéeriel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d'essence ni d'autres vape-
rurs ou liquides inflammables dans le voisinage de cet
appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
Ne pas tenter d'allumer d'appareil.
Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batimentvous
vous trouvez.
Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appe-
lez le service dos incendies.
L'installation et service doit être exécuté par un quali-
fié installer, agence de service ou le fournisseur de gaz.
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - MODEL #E-FV44I ECHO SERIES

INSTALLATION & OPERATING INSTRUCTIONS Full View Direct Vent Gas Fireplace Insert With Premium Texture Fiber Logs Combustion System MODEL #E

Page 2 - TABLE OF CONTENTS

Part #85-03-00855 9 Chimney Flashing and cap (See FIGURE BELOW) The vent kits include a trim-able flashing. Measure, trim and shape flashing to fit

Page 3 - SPECIFICATIONS

Part #85-03-00855 10 14. Remove the Vent Adapter by removing two 5/16” Hex Bolts and sliding Vent Adapter to-wards rear of Insert. 15. Tightly sec

Page 4

Part #85-03-00855 11 18. You are now ready to hook up the Insert to gas supply. Be sure gas plumbing instructions and all state and local codes ha

Page 5 - ...CAUTION

Part #85-03-00855 12 sert, the existing and approved hearth protection will provide adequate floor protection. If a raised hearth extends less than

Page 6 - APPROVED MANTEL PROFILES

Part #85-03-00855 13 GAS PRESSURE CHECKING REQUIREMENTS A pressure tap for checking gas pressure is located on the main gas valve. A qualified insta

Page 7 - 1/16 920 52 1/8 1326

Part #85-03-00855 14 GAS PRESSURE REQUIREMENTS One major cause of operating problems with gas appliances can be improper gas pressure! Such problems

Page 8 - INSTALLATION INSTRUCTIONS

Part #85-03-00855 15 HIGH ALTITUDE INSTALLATIONS For installations from 610-1370 meters (2000-4500 ft.) the orifice sizes (DMS) for natural gas are

Page 9 - AS LISTED IN FIGURES BELOW:

Part #85-03-00855 16 INSTALLATION CHECK OFF LIST The following check list must be completed prior to initial lighting of the Fireplace Insert, or ma

Page 10 - Chimney Flashing and cap

Part #85-03-00855 17 2.) PULL3.) ROTATE4.) RELEASE1.) INSERTDOOR REMOVAL AND REPLACEMENT CAUTION: Do not operate the appliance with glass removed,

Page 11 - Part #85-03-00855

Part #85-03-00855 18 FV-44i LOG SET INSTALLATION INSTRUCTIONS FOLLOW EACH STEP DEPICTED IN THE DIAGRAMS, BELOW, TO INSTALL THE LOG SET. CAUTION: LOGS

Page 12

Part #85-03-00855 1 TABLE OF CONTENTS SPECIFICATIONS ...

Page 13 - NAT. L.P. NAT. L.P

Part #85-03-00855 19

Page 14

Part #85-03-00855 20

Page 15

Part #85-03-00855 21

Page 16

Part #85-03-00855 22

Page 17

Part #85-03-00855 23

Page 18 - 1.) INSERT

Part #85-03-00855 24

Page 19

Part #85-03-00855 25

Page 20

Part #85-03-00855 26

Page 21

Part #85-03-00855 27 PLACE SMALL COALS ON TOP OF FLOOR BRICK PANELS AND CLOSE TO GRATE BOTTOM TO SIMULATE A COAL BED.

Page 22

Part #85-03-00855 28 BEFORE YOU BEGIN Read this entire manual before you use your new fireplace insert(especially the section “Safety Precautions”).

Page 23

Part #85-03-00855 2 SPECIFICATIONS MODEL E-FV-44i High Fire - Adj. to - Low Fire BTUH ...NAT

Page 24

Part #85-03-00855 29 REMOTE TRANSMITTER OPERATING INSTRUCTIONS TO TURN ON THE APPLIANCE: 1. Press the ON/OFF button. The transmitter display will

Page 25

Part #85-03-00855 30 MANUAL BYPASS OF THE REMOTE SYSTEM If the remote transmitter is misplaced or lost, the appliance can be turned on manually by s

Page 26

Part #85-03-00855 31 “FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Install

Page 27

Part #85-03-00855 32 ATTENTION! The transmitter and receiver are RADIO FREQUENCY DEVICES. Placing the receiver in or near metal may severely reduce

Page 28

Part #85-03-00855 33 FV-44i GAS IGNITION SYSTEM WIRING DIAGRAM

Page 29 - BEFORE YOU BEGIN

Part #85-03-00855 34 MAINTENANCE 1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED. The following procedures must be performed each year by a Mend

Page 30 - TO TURN ON THE APPLIANCE:

Part #85-03-00855 35 5554LP Pilot Orifice[#977.168]MotorizedLP PressureRegulator[10.0-5.5"WC]# 907.012Burner Orifices#65-14-00054[54 DRILL]#65-1

Page 31

Part #85-03-00855 36 Use an Alan WrenchTo loosen and removeNG Pilot Orifice. InstallLP Pilot Orifice, TightenDown.Pull Pilot Hood UPand lift UP off t

Page 32 - DETAIL C

Part #85-03-00855 37 LP PRESSURE REGULATOR CONVERSION INSTRUCTIONS WARNING: Failure to position the parts in accordance with these diagrams or failur

Page 33

Part #85-03-00855 38 LP GAS PRESSURE REQUIREMENTS Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only access

Page 34

Part #85-03-00855 3 SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW th

Page 35 - MAINTENANCE

Part #85-03-00855 39 WARNING DO NOT PROCEED WITH OPERATION OF THIS FIREPLACE UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS! CHECKING FOR NO

Page 36 - REMOVE LOG GRATE

Part #85-03-00855 40 GAS INLETGAS SHUTOFF CONTROLGAS SHUTOFF CONTROLROTATE TO CLOSEHOLE FORTOOLTIP INDICATESVALVE ORIENTATION EMERGENCY GAS SHUTOFF C

Page 37 - VIEW FROM OUTSIDE FIREBOX

Part #85-03-00855 41 CUSTOMER INFORMATION AND TROUBLE-SHOOTING OVER FIRING/UNDER FIRING OF BURNER NEVER "over fire" units by adjusting gas

Page 38

Part #85-03-00855 42 GAS FLAME ADJUSTMENT During the initial installation, the air shutter opening should be checked to be certain that the shutter

Page 39 - Burner Ports

Part #85-03-00855 43 Replacement and Service Parts Note: Glass replacement is to be done by ordering the complete Glass Frame assembly #HA-58-00029.

Page 40

Part #85-03-00855 44 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfacti

Page 41 - CONTROL

Part #85-03-00855 45 TAPE SHUT --------------------------------------------------------------------------------------------------

Page 42

Part #85-03-00855 46 MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY MENDOTA GAS FIREPLACE INSERT MODEL: FV-44i NAT. & L.P. Mendot

Page 43 -

Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Website: www.johnsongas.com or www.mendotahearth.com

Page 44

Part #85-03-00855 4 CONGRATULATIONS You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace. This elegant, high

Page 45

Part #85-03-00855 5 GENERAL INFORMATION Your Mendota Gas Fireplace Insert has a state-of-the-art direct vent, sealed combustion system. This advan

Page 46

Part #85-03-00855 6 MENDOTA FV-44i GAS DIRECT VENT FIREPLACE INSERT SPECIFICATIONS & CLEARANCES FV-44i Faceplate Dimensions A B Inches

Page 47 - MENDOTA GAS FIREPLACE INSERT

Part #85-03-00855 7 INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local, state and national codes. Refer to the national

Page 48 - or www.mendotahearth.com

Part #85-03-00855 8 FLUE VENTING The FV-44i Insert must be vented vertically to the outside and must use the Mendota Co-Linear flexible ducting syste

Comments to this Manuals