"LABEL REPRESENTATION"
DXV42
Also for use in mobile (manufactured) homes after first sale of home.
Tested to ANSI Z21.88 (2002) – CSA 2.33 (2002)
_________________________________________________
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property dam-
age, personal injury, or loss of life. Refer to the owner's information manual provided with this appliance.
Installation and service must be performed by a qualified installer, service agency or the gas supplier. Use
only glass assemblies certified for use with this appliance. Do not operate with glass panel(s) removed,
cracked, or broken.
NOT FOR USE WITH SOLID FUEL
NATURAL GAS
PROPANE GAS
Input Rating (Btu/hr) 0-610 m 40,000 38,500
Orifice (DMS) 0-610 m 30 48
Manifold Pressure (in w.c.) 3.5 10.0
Manifold Pressure, low (in w.c.) 1.7 3.6
Minimum Inlet Pressure (in w.c.) 5.0 11.0
_______________________________________________
This appliance is equipped for installation at 0-610 meters. This appliance must be installed in accordance with local codes if
any; If not, follow ANSI Z223.1. Mobile (Mfg.) home installations must adhere to Title 24 CFR, Part 3280.
_______________________________________________
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Unit to floor 0 in. Unit to enclosure sidewalls 0 in.
Unit to enclosure sidewall 0 in. Unit top to ceiling 0 in.
Vent to enclosed 1 in. Wall Pass-Through to framing 1 in.
Vent to adjacent sidewall 4 in. Mantle above discharge air opening 9 in.
CAUTION: Hot while in operation. Do not touch. Keep children, clothing, furniture, and flammable liquids or vapors away.
Electrical Rating (Courant nominal): 120 volts 60 Hz Less than 1 Ampere
_______________________________________________
JOHNSON GAS APPLIANCE
CEDAR RAPIDS, IOWA
DO NOT REMOVE OR COVER THIS LABEL
WH# __________________