FULLVIEW RECTANGLE DIRECT VENT GAS FIREPLACE HEATER
Model FV41
INSTALLATION INSTRUCTIONS MANUAL
DOCUMENT NO. FV41-IM-0610
In the Commonwealth of Massachusetts:
Installation must be performed by a licensed plumber or
gas fitter;
A CO detector shall be installed in the room where the
appliance is installed.
WARNING: Improper installation, adjustment, altera-
tion, service or maintenance can cause injury or prop-
erty damage. Refer to this manual. For assistance or
additional information consult a qualified installer, ser-
vice agency or the gas supplier.
CAUTION
THESE INSTRUCTIONS ARE TO REMAIN WITH
THE HOMEOWNER.
WARNING
If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage,
personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Open windows.
Do not touch electrical switches.
Do not try to light any appliance.
Extinguish any open flame.
Do not use the phone in your building.
Immediately call your gas supplier from a neighbor's
SKRQH)ROORZWKHJDVVXSSOLHU¶VLQVWUXFWLRQV
If you cannot reach your gas supplier, call the fire
department.
FOR YOUR SAFETY
A qualified installer, service agency, or the gas suppli-
er must perform installation and service.
Do not store or use gasoline or other flammable va-
pors and liquids in the vicinity of this or any other ap-
pliance.
WARNING
Do not operate this appliance with the glass removed,
cracked or broken. A licensed or qualified person
should do replacement of glass.
WARNING
Mendota gas fireplaces are heat producing appliances.
Do not burn wood, paper or other materials in this fire-
place. This fireplace is designed as a supplement
heat source. It is advisable to have an alternative pri-
mary heat supply.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control, which has been under water.
The installation must conform with local codes or, in
the absence of local codes, with the current National
Fuel Gas Code, ANSI Z223.1, or the current Natural
Gas and Propane Installation Code, CSA B149.1
Page view 0
1 2 3 4 5 6 ... 51 52

Summary of Contents

Page 1 - Model FV41

1 | Page FULLVIEW RECTANGLE DIRECT VENT GAS FIREPLACE HEATER Model FV41 INSTALLATION INSTRUCTIONS MANUAL DOCUMENT NO. FV41-IM-0610 In the Co

Page 2

10 | Page MANTEL CLEARANCES Mantel Clearances for this fireplace may be measured from the top of the convection air opening or the floor level of thi

Page 3 - TABLE OF CONTENTS

11 | Page CLEARANCES TO COMBUSTIBLES FROM APPLIANCE SURFACES Figure 2: Clearances to Combustibles 0" CLEARANCEFROM TOP STANDOFFS1/2" CL

Page 4

12 | Page PLANNING THE INSTALLATION When planning on appliance installation, it is necessary to determine the following information before installing

Page 5

13 | Page ROUGH FRAMING DIMENSIONS Rough Framing Dimensions The Rough Framing Dimensions must be main-tained to allow this fireplace to slide into th

Page 6 - 6

14 | Page INNER FINISHINGGUIDES(TOP, L &R)OUTER FINISHINGGUIDES (TOP, L & R)FRAMING DEPTH and FINISHING GUIDES The framing depth for this fi

Page 7 - MODEL FV41

15 | Page FINISHING MATERIALS INSTALLATION All finishing PDWHULDOVWKDWVXUURXQGWKLVILUHSODFH¶Vrectangle profile must extend out from the face sur

Page 8 - CONGRATULATIONS

16 | Page 18" min. Non-combustible Hearthprotection required [SEE HEARTHPROTECTION PAD R-RATING, PAGE 12]112" MAX. THICK HEARTH PAD (MIN R-

Page 9 - 9

17 | Page GENERAL INFORMATION Your Mendota Gas Fireplace has a state-of-the-art co-axial direct vent, sealed combustion system. This advanced and hi

Page 10 - MANTEL CLEARANCES

18 | Page FRONT110VAC INLET14-2 CABLE REQ'DGAS LINE INLET1/2" FNPT REQ'D12116915161414GAS SUPPLY REQUIREMENTS Correct gas pressure and

Page 11

19 | Page GAS PRESSURE REQUIREMENTS One of the main causes of operating problems with gas appliances can be improper gas pressure! Problems such as c

Page 12 - FIRE RISK- ODOR RISK

2 | Page SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW these instruc

Page 13 - MIN. DEPTH

20 | Page GENERAL INSTALLATION INSTRUCTIONS CAUTION: Each installation must conform to all local, state and national codes. Refer to the national f

Page 14 - OUTER FINISHING

21 | Page GENERAL FLUE VENTING INSTRUCTIONS The Mendota Fireplace must be vented using the Mendota approved vent system components. Approved brands

Page 15 - Figure 6:

22 | Page EXTERIOR VENT LOCATIONS AND RESTRICTIONS ALL MEASUREMENTS FROM CENTER-LINE OF VENT CAP - Vent Terminal - Air Supply Inlet - Area wher

Page 16 - FIGURE 8

23 | Page FLUE VENTING COMPONENTS IDENTIFICATION HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, pleas

Page 17 - GENERAL INFORMATION

24 | Page FOUR 90° ELBOWS MAX IF VERTICALLY TERMINATED IN ZONE "B".THREE 90° ELBOWS MAX IF HORIZONTALLY TERMINATED IN ZONE "B".NO

Page 18 - GAS SUPPLY REQUIREMENTS

25 | Page IMPORTANT VENTING CONFIGURATION NOTES See Figure 14 [MASTER FLUE VENTING REQUIREMENTS CHART]. HIGH ALTITUDE INSTALLATION INFORMATION: Prior

Page 19 - GAS PRESSURE REQUIREMENTS

26 | Page ZERO VERTICALHORIZONTAL TERMINATIONVERTICAL RISEHORIZONTAL TERMINATIONZERO VERTICALDUAL 90° ELBOWSVERTICAL TERMINATIONVERTICAL RISEDUAL 90°

Page 20 - 1/2" FNPT REQ'D

27 | Page HZERO VERTICALHORIZONTAL TERMINATIONH = 18 INCHES MAXIMUMZERO RISE HORIZONTAL TERMINATION The FV-41 Fireplace must be installed by a qualif

Page 21

28 | Page VONE(1) 90° ELBOWTOP VENTHORIZONTAL TERMINATIONHVERTICAL RISE HORIZONTAL TERMINATION The minimum vertical section required to be connected

Page 22

29 | Page Figure 19 Figure 20 APPROVED

Page 23

3 | Page TABLE OF CONTENTS SAFETY AND WARNING INFORMATION 2 SPECIFIC REQUIREMENTS FOR THE COMMON WEALTH OF MASSACHUSETTS 5 FV-41 FULL VIEW GAS FIRE

Page 24 - ZONE "A"

30 | Page VERTICAL THROUGH-THE ROOF VENTING The maximum vertical run of vent pipe is 51 ft. from the top of the fireplace. The fireplace will suppor

Page 25

31 | Page . Figure 21 1,2,3,4,513159,10111261 FEETMAX.

Page 26 - APPROVED VENT SYSTEMS

32 | Page H2H1V1FOUR 90° ELBOWS, VERTICAL TERMINATION2'4'- 40'3'V1(12" MIN.)12"H1+H2+H35'249'3'58'4

Page 27 - H = 18 INCHES MAXIMUM

33 | Page FV-41 DOOR OPERATION TO REMOVE DOOR 1. Use the glass latch tool to disconnect the spring latches from the glass frame. Insert tool into ho

Page 28 - TOP VENT

34 | Page INSTALLATION CHECK OFF LIST  Co-axial vent rigid pipe, wall vent cap or roof vent cap must be installed by a Mendota approved person in ac

Page 29 - APPROVED

35 | Page BLOWER SYSTEM INFORMATION WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and

Page 30

36 | Page PULL OUT 1/8"ROTATE CLOCKWISE,RELEASE.ACCENTLIGHTHOUSINGDAMPERPOSITIONINDICATORHook LatchTool In Hole.CCW OPENS DAMPERCW CLOSES DAMPER

Page 31

37 | Page TROUBLE SHOOTING THE FV-41 FIREPLACE & MAINTENANCE INFORMATION SYMPTOM PROBABLE CAUSES CORRECTIVE ACTION 1. Thin black coating (so

Page 32 - ELBOWS

38 | Page MAINTENANCE 1. ANNUAL MAINTENANCE OF MENDOTA UNITS IS REQUIRED. The following procedures must be performed each year by a Mendota approve

Page 33 - 1.) INSERT

39 | Page 1. PUSH REAR END OF BAFFLE BRICK UPWARD ABOUT 1/4 INCHES.2. TIP LEFT BRICK PANEL INWARD AND RELEASE CAREFULLY.1.REMOVE 8 SCREWS THAT SECURE

Page 34

4 | Page FLAME APPEARANCE ADJUSTMENT 36 FLAME APPEARANCE ADJUSTMENT- AIR SHUTTER ADJUSTMENTS 36 FLAME APPEARANCE ADJUSTMENT- EXHAUST DAMPER ADJUSTM

Page 35 - FV-41 BLOWER WIRING DIAGRAM

40 | Page Use an Alan WrenchTo loosen and removeNG Pilot Orifice. InstallLP Pilot Orifice, TightenDown.Pull Pilot Hood UPand lift UP off the base.WAS

Page 36 - FLAME APPEARANCE ADJUSTMENT

41 | Page LP PRESSURE REGULATOR CONVERSION INSTRUCTIONS WARNING: Failure to position the parts in accordance with these diagrams or failure to use on

Page 37

42 | Page LP GAS PRESSURE REQUIREMENTS Inlet and manifold gas pressure checking taps are located on gas valve. These ports are only accessible from t

Page 38 - MAINTENANCE

43 | Page WARNING DO NOT PROCEED WITH OPERATION OF THIS FIREPLACE UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS! CHECKING FOR NORMAL BURNER

Page 39 - REMOVE LOG GRATE

44 | Page FV-41 VALVE ASSEMBLY REPLACEMENT PARTS FV-41 VALVE ASSEMBLY REPLACEMENT PARTS LIST ITEM QTY PART NUMBER DESCRIPTION 1 1 HA-77-00159

Page 40 - VIEW FROM OUTSIDE FIREBOX

45 | Page FV-41 GAS IGNITION SYSTEM WIRING DIAGRAM

Page 41

46 | Page TAB #2USE LARGE PLIERS TOBEND DOWN (4) TABSAS SHOWNGLASSGASKETGLASS FRAME ASSEMBLY REPAIR AND REPLACEMENT TO REPLACE DAMAGED GLASS 1. Be

Page 42 - Burner Ports

47 | Page LISTING LABEL INFORMATION The model information regarding your specific appliance can be found on the rating plate, which is located inside

Page 43

48 | Page MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfaction, this For

Page 44 - 44

49 | Page NOTES

Page 45 - 45

5 | Page Specific Requirements for the Common Wealth of Massachusetts The information in this section applies to all installations performed in the C

Page 46 - AS SHOWN

50 | Page TAPE SHUT ----------------------------------------------------------------------------------------------------------

Page 47 - LISTING LABEL INFORMATION

51 | Page MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY MENDOTA FV-41 DIRECT VENT FIREPLACE Mendota Division of Johnson Gas Applianc

Page 48

52 | Page Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division WEBPAGE: www.johnsongas.com or

Page 49 - 49

6 | Page FV-41 FULL VIEW GAS FIREPLACE DIMENSIONS OVERALL APPLIANCE DIMENSIONS AND FEATURES VISIBLE GLASS AREA26-1/4" X 29-1/2"[775 sq. i

Page 50

7 | Page TECHNICAL SPECIFICATIONS FOR FV-41 MODEL FV41 High Fire - Adjustable to - Low Fire BTUH. (MODEL FV-41) NAT. GAS 40,00

Page 51 - 51

8 | Page CONGRATULATIONS You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace. This elegant, highly efficien

Page 52

9 | Page FV41 DIRECT VENT GAS FIREPLACE GENERAL APPLIANCE SPECIFICATIONS HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes hig